An audiogram is a graph that shows how softly you can hear sounds at different pitches. It is one of the main results produced during a hearing evaluation and can help identify whether hearing changes affect one or both ears, which pitches are involved, and what type of hearing loss may be present.
For residents in Southlake, TX, understanding the basic layout of an audiogram can make a hearing test report much easier to follow. The graph may look technical at first, but its key features are fairly straightforward.
What does an audiogram measure?
An audiogram measures hearing sensitivity, not simply whether a person can hear or cannot hear. During the test, tones at different pitches are presented at gradually softer levels. The lowest level heard for each pitch is marked on the graph.
The two main measurements are:
- Frequency, measured in hertz (Hz), which describes pitch
- Hearing level, measured in decibels hearing level (dB HL), which describes how loud a sound must be for it to be heard
Low frequencies represent deeper sounds, such as a bass instrument or a low-pitched voice. High frequencies represent sharper sounds, such as a bird chirp, a child’s voice, or the clarity of consonants in speech.
The test usually examines frequencies from about 250 Hz through 8,000 Hz, although additional frequencies may be tested when clinically appropriate.
How do you read the graph?
Frequency is shown across the horizontal axis. Lower pitches are on the left, and higher pitches are on the right.
Hearing level is shown on the vertical axis. The scale is unusual because better hearing appears toward the top of the graph. A result near 0 dB HL generally indicates that a very soft sound was heard. A result farther down the graph means a louder sound was needed.
The symbols usually represent each ear separately:
- The right ear is commonly marked with red circles
- The left ear is commonly marked with blue Xs
The exact symbols can vary, especially when bone-conduction testing or masking is used. Your report may also show arrows or brackets if a sound was not heard at the equipment’s highest available output.
A line connecting the symbols helps show the overall pattern, but the individual points are more important than the appearance of the line alone.
What do normal and abnormal results look like?
A result is generally considered within the typical range when thresholds fall between approximately -10 and 15 dB HL, although interpretation depends on age, test conditions, and the full clinical picture.
Common descriptive categories include:
- Slight: approximately 16 to 25 dB HL
- Mild: approximately 26 to 40 dB HL
- Moderate: approximately 41 to 55 dB HL
- Moderately severe: approximately 56 to 70 dB HL
- Severe: approximately 71 to 90 dB HL
- Profound: 91 dB HL or greater
These ranges are useful guidelines, not a complete diagnosis. A person with a mild high-frequency loss may have more difficulty understanding conversation in restaurants, classrooms, or busy family gatherings than the label “mild” suggests.
Why does the shape of the audiogram matter?
The pattern across frequencies is called the configuration of hearing loss. The configuration often provides more practical information than the average result.
A flat pattern means hearing is reduced by a similar amount across pitches. A sloping pattern means hearing is better in the low frequencies and poorer in the high frequencies. This is common in age-related or noise-related hearing changes.
A rising pattern means lower frequencies are affected more than higher frequencies. A notched pattern may show poorer hearing at particular high frequencies, sometimes associated with long-term noise exposure.
Two people can have the same average hearing level but different communication difficulties because their losses affect different pitches.
What are air conduction and bone conduction?
Most people first complete air-conduction testing using headphones or small insert earphones. This measures the entire hearing pathway, including the outer ear, middle ear, inner ear, and auditory nerve.
Bone-conduction testing uses a small vibrator placed behind the ear or on the forehead. It sends vibrations through the skull to stimulate the inner ear more directly.

Comparing these results helps identify the type of hearing loss:
- Conductive hearing loss involves the outer or middle ear. Earwax blockage, fluid, eardrum problems, or other middle-ear conditions can contribute.
- Sensorineural hearing loss involves the inner ear or auditory nerve. Age-related changes, noise exposure, certain illnesses, and some medications may play a role.
- Mixed hearing loss includes both conductive and sensorineural components.
The difference between air- and bone-conduction thresholds is called an air-bone gap. That gap can provide useful clues about how sound is traveling through the ear.
What do speech test results mean?
A hearing evaluation often includes speech testing in addition to pure tones. Two results commonly appear on the report.
Speech reception threshold is the softest level at which a person can correctly repeat familiar two-syllable words. It is usually compared with the pure-tone results to see whether the findings are consistent.
Word recognition measures how accurately a person repeats single words at a comfortable listening level. A high score suggests that speech is relatively clear when loud enough. A lower score may indicate that increasing volume alone will not fully solve the communication difficulty.
Word recognition can also vary depending on fatigue, attention, language familiarity, and the listening environment. It should be interpreted alongside the rest of the evaluation.
What are tympanometry and other tests?
An audiogram focuses mainly on hearing sensitivity. Other tests may be added to examine different parts of the hearing system.
Tympanometry evaluates middle-ear function by changing air pressure in the ear canal and measuring how the eardrum responds. It can help identify pressure problems, fluid, reduced eardrum movement, or other middle-ear concerns.
Acoustic reflex testing measures involuntary muscle responses to loud sounds.
Otoacoustic emissions assess activity from the inner ear’s outer hair cells. These tests are especially useful when a person cannot provide reliable behavioral responses, including some infants and young children.
A complete interpretation depends on the combination of test results, symptoms, medical history, and an examination of the ear canal and eardrum.
Does a normal audiogram always mean hearing is normal?
No. A standard audiogram does not measure every aspect of hearing.
A person may have thresholds in the typical range but still struggle with speech in background noise, fast conversation, reverberant rooms, or group settings. Listening effort, tinnitus, auditory processing concerns, attention, and certain medical conditions can affect communication without producing a clear hearing loss on the graph.
Southlake households may notice these challenges during large family gatherings, school activities, outdoor events, or conversations near air-conditioning equipment and other steady background noise. In those situations, the ability to separate speech from competing sound may matter as much as the ability to detect a quiet tone.
When should hearing changes be evaluated promptly?
A gradual change in hearing deserves attention, especially if conversations are frequently missed, television volume keeps increasing, or one ear seems noticeably different from the other.
Sudden hearing loss, particularly in one ear and especially when accompanied by ringing, dizziness, or a blocked sensation, should be treated as urgent. Prompt medical evaluation is important because some causes are time-sensitive.
An audiogram is most useful when viewed as part of a broader evaluation. The graph can describe hearing sensitivity, but the meaning of the results depends on symptoms, ear health, communication needs, and how hearing functions in everyday settings.